Applied Sciences Group is a leading provider of automation solutions to commercial and industrial applications.
Case Study: AC Drive Network Driver Development

Project Description:
A customer needed to network together a series of AC drives and a SCADA package. For the drives being used (CT drives) no software existed that could link them to a SCADA or other control package. The customer requested that the network communicate to an Intellution SCADA package.

Approach:
Applied Sciences Group designed and developed a fully functional X-Link Driver for a network of AC drives, as well as an Intellution FIX Driver, Loadable Database Block, and Graphical Dynamo. The CT-Net driver development included all software engineering, programming, and support.

X-Link Driver Development
Construction of the driver for the X-Link gateway involved adding components to the X-Link kernel to enable communications via X-Link between dissimilar networks. The custom CT-Net driver allows users to communicate from CT-Net through X-Link to any communications scheme that has an X-Link driver.
Intellution FIX Driver
The transfer of information between the CT drives and the FIX Database were provided. An Intellution-style I/O driver was produced which communicates with Scan, Alarm and Control (SAC) through Driver Image Tables, representing a significant amount of work in addition to the communications DLL. Once completed, the driver was outwardly identical to other FIX drivers and was installed/configured through the System Configuration task (SCU). Applied Sciences Group engineers had attended the I/O driver instructional seminars provided by Intellution and Applied Sciences Group possessed the required I/O Driver Tool kit and manuals.
Intellution Loadable Database Block
A set of appropriate database blocks (analog inputs, analog outputs, and calculation blocks for scaling) was developed to provide flexibility. End users were ultimately provided with a generic set of database files (packaged as a text files) with the ability to be imported into any Intellution Database.
Intellution Graphical Dynamo
A Graphical Dynamo was produced to aid in screen development. This was accomplished by working closely with the customer to achieve desired results.

Results:
This effort successfully resulted in a general-purpose X-Link driver package that allows communication between CT drives and other devices on an X-Link network. Close cooperation and communication with the customer was essential to the project's success.

 
   Case Studies
Casting Shop Recipe Control and DAQ (AB, FIX)
AC Drive Network Driver Development
High-Speed Chopper Lines Upgrade
Kiln Control System and Operator Interface (TI-545, Xycom)
Mesh Belt Conveyor Furnace Control System
Mineral Exploration
Wafer Mapping Software Interface
Pump Station Control System
Pharmaceutical Freeze Dry System
Automotive Axle Tracking Control System
     

HomepageDocumentsSite MapContact Applied Sciences Group

© 2004-2008 Applied Sciences Group, Inc. All Rights Reserved.
4455 Genesee St. • Bldg 6 • Buffalo, NY 14225 • Ph: 716-626-5100

President's Message Our History Management Team Our Staff Our Clients Career Opportunities
Automation Solutions High-Tech Solutions Energy Mgmt Solutions Expert Witness Project Mgmt Custom Training Case Studies FAQ
In the News Events Community Media Kit
Our Alliances Our Memberships
Info Request Form Visitor Information